An EagerLED resource. Public-source references and technical guidance; not a binding quotation. Read our methodology.

Quick answer

For a shallow recess, start with the EA250WH5: its documented cabinet is 30 mm deep and the source says the opening needs no deep recess. EA640H1 is a 48 mm front-service indoor wall with 640 × 480 mm cabinets and six 320 × 160 mm modules; its source separately says to allow extra depth for structure and ventilation. Both need installed assembly depth, front clearance, pitch and layout confirmed in writing.

Sources used: EA640H1 specs; EA250WH5 specs

Depth and cabinet format decide the shallow-recess fit

Start with the recess constraint, not the series name. The EA250WH5 source describes a 30 mm ultra-thin cabinet and says the opening needs no deep recess. The EA640H1 source describes a 48 mm cabinet and separately advises allowing extra depth for structure and ventilation. Cabinet depth is only one number in the installation, so ask for the installed assembly depth, mounting interface and ventilation clearance for the exact wall.

Cabinet format also changes how a shallow wall is planned. EA250WH5 uses one 250 × 250 mm module across six cabinet formats, from 500 × 250 mm up to 1000 × 500 mm. EA640H1 uses a 640 × 480 mm die-cast cabinet carrying six 320 × 160 mm modules in a two-by-three layout. EA640H1 evidence also states that its 4:3 cabinets form a 2,560 × 1,440 mm 16:9 wall in a four-wide, three-high array of 12 cabinets. For a specific recess, ask for a layout drawing that shows the cabinet matrix, module grid and any right-angle or column faces, because a flat-face cabinet count does not establish the quantity for those layouts.

Pitch range, module protection and service access

The two families overlap only partly on pixel pitch. EA250WH5 offers seven pitches from P1.25 GOB to P3.91. EA640H1 offers P1.25 to P2.5, with GOB on P1.25 to P2 models and a standard SMD2020 module on P2.5. If the recess wall is viewed close, match the pitch to the closest viewer and the smallest text; if the wall is watched from farther back, the wider EA250WH5 pitch range may give more room to choose. Ask the quotation to name the exact pitch and module protection rather than a family-level range.

Service access is the second shared constraint. EA250WH5 modules, power supplies and control components are reachable from the front with a suction tool, so no maintenance aisle is needed behind the wall. EA640H1 modules are removed from the viewing side with a vacuum service tool, so no rear service corridor is needed, and its modules connect to the cabinet HUB without ribbon cables. EA250WH5 also uses a direct HUB module connection without separate power cords or ribbon cables. For a recess, confirm the front clearance needed to remove modules, and put spare modules on their own quote line.

Depth, format and service comparison for a shallow recess

Decision EA250WH5 evidence EA640H1 evidence What to request
Cabinet depth 30 mm ultra-thin cabinet; source says the opening needs no deep recess. 48 mm deep cabinet; source says to allow extra depth for structure and ventilation. State cabinet depth separately from installed assembly depth, mounting interface and ventilation clearance.
Cabinet and module format Six cabinet formats from 500 × 250 mm up to 1000 × 500 mm; one 250 × 250 mm module. 640 × 480 mm die-cast cabinet with six 320 × 160 mm modules in a two-by-three layout. Name exact cabinet dimensions, module footprint and pitch in the quotation.
Front service Modules, power supplies and control components are reachable from the front with a suction tool; no maintenance aisle behind the wall. Modules are removed from the viewing side with a vacuum service tool; no rear service corridor is needed. Confirm service route and front clearance for the exact installed position.
Pitch range and module protection Seven pitches from P1.25 GOB to P3.91. P1.25 to P2.5; GOB on P1.25 to P2 models; SMD2020 on P2.5. Confirm selected pitch and module protection rather than a family range.
Mounting and alignment Wall-mounted, suspended and column installation; right-angle and column configurations are documented. Die-cast aluminum cabinets join with quick locks and align at the joints; 4:3 cabinets build a 16:9 array. Request a layout drawing and cabinet count for flat, right-angle or column faces as applicable.
Quote inclusions Price is quoted per project and depends on pixel pitch, wall size, cabinet quantity, control system, spare modules and shipping. Quote request asks for wall width and height, viewing distance, preferred pitch and delivery address, with an itemized quote covering cabinets, controller, spare modules and freight. Ask for separate lines for cabinet, module, service, layout, control, spares and freight.

What to put in a shallow-recess quotation

For a shallow recess, the quotation should separate cabinet depth from installed assembly depth, and should name the mounting method, service route, front clearance, layout count, pitch and module protection. EA250WH5 documents six cabinet formats, wall-mounted, suspended and column installation, and right-angle and column configurations. EA640H1 documents quick-lock die-cast cabinets and a 4:3 cabinet that can build a 16:9 wall. A flat-face cabinet count does not establish the quantity for a right-angle or column layout; ask for the count per face or wrap. Use the same line structure when you compare an indoor LED screen price.

Spares and layout evidence should be requested in the same document. EA640H1 evidence advises ordering spare modules in the same pitch to keep brightness and colour even. EA250WH5 evidence says every format uses the same 250 × 250 mm module, so the quotation should still name the exact cabinet format, module and pitch. Ask for a written layout drawing, the cabinet matrix, the service tool and the front clearance for the installed position. If the wall will be viewed off-axis, ask for the viewing angle for the exact quoted model; EA250WH5 lists 160° and EA640H1 lists 140°.

When the deeper EA640H1 can still be the better choice

EA640H1 is not excluded from a recess simply because it is deeper. Its 48 mm cabinet is front-service, and the source says modules are removed from the viewing side, so it can suit a wall that sits close to the wall or a shallow service space if the mounting design allows the extra depth for structure and ventilation. The important condition is the total installed depth, not the cabinet figure alone. Ask the supplier to confirm the recess depth requirement for the exact EA640H1 mounting method.

The larger 640 × 480 mm cabinet may also be the better fit when the target is a standard 16:9 array and the buyer wants fewer cabinet types. Its 4:3 cabinets form a 2,560 × 1,440 mm 16:9 wall in a four-wide, three-high array of 12 cabinets. EA640H1 covers P1.25 to P2.5 with GOB on P1.25 to P2 and SMD2020 on P2.5, and it lists at least 3,840 Hz refresh, 14-bit grayscale, 600 to 800 cd/m² brightness and a 140° viewing angle. Those are documented series specifications to confirm for the exact pitch and wall. For the recess wall, ask how cabinets are aligned and how seam and alignment will be accepted.

Shallow-recess scenarios and what to confirm

Scenario What to confirm
Very shallow finished recess Compare the EA250WH5 30 mm cabinet against the EA640H1 48 mm cabinet, then request installed assembly depth, mounting interface and ventilation clearance for the exact position.
Recess can accommodate 48 mm plus structure EA640H1 can be considered; confirm the 640 × 480 mm cabinet layout, quick-lock assembly and the required extra depth for structure and ventilation.
Wall close to the viewer Confirm pitch for the closest viewer; EA250WH5 GOB pitches serve close viewing and P2.5 to P3.91 suits about 3 m, while EA640H1 places P1.25 to P1.86 at about 2 to 3 m and P2 to P2.5 at roughly 3 to 4 m.
Column wrap or right-angle face EA250WH5 documents right-angle and column configurations; request a layout drawing and cabinet count per face. Do not carry a flat-wall count to a column or corner build.
Rear access unavailable Both models document front service; confirm the service tool and front clearance for the exact cabinet and mounting method.
Spare and replacement plan Order spare modules by exact pitch and cabinet or module format; EA640H1 evidence advises same pitch to keep brightness and colour even.

EA640H1 4-wide by 3-high cabinet count

Illustrative calculation: 4 × 3 = 12 cabinets. Source states a four-wide, three-high array of 12 cabinets for a 2,560 × 1,440 mm 16:9 wall.

EA640H1 16:9 wall width

Illustrative calculation: 4 × 640 = 2560 mm. Source states four 640 mm cabinets wide form a 2,560 mm wall.

EA640H1 16:9 wall height

Illustrative calculation: 3 × 480 = 1440 mm. Source states three 480 mm cabinets high form a 1,440 mm wall.

Buyer checklist

  • Ask for installed assembly depth, mounting interface and ventilation clearance for the exact wall, not only cabinet depth.
  • Name the exact model, cabinet dimensions, module footprint and pitch in the quotation.
  • Confirm the front-service route, tool and clearance for the recess position.
  • Request a layout drawing and cabinet count for flat, right-angle or column faces as applicable.
  • Put spare modules on a separate line matched to the quoted pitch and module format.
  • If cameras or off-axis seats matter, ask for refresh, grayscale and viewing angle for the exact quoted pitch.

Frequently asked questions

Which model is thinner for a shallow recess: EA250WH5 or EA640H1?

EA250WH5 evidence documents a 30 mm cabinet; EA640H1 evidence documents a 48 mm cabinet. The EA250WH5 source says the opening needs no deep recess, while the EA640H1 source says to allow extra depth for structure and ventilation. Compare installed assembly depth, not cabinet depth alone.

Does a 30 mm cabinet mean the EA250WH5 wall needs no mounting depth?

No. The 30 mm figure is cabinet depth. The EA250WH5 source says the cabinet mounts almost flush and the opening needs no deep recess, but the quotation still needs installed assembly depth, mounting interface and ventilation clearance for the exact wall.

Can EA640H1 front service work in a shallow recess?

EA640H1 modules are removed from the viewing side with a vacuum service tool, so no rear service corridor is needed. The cabinet is 48 mm deep, and the source separately advises allowing extra depth for structure and ventilation. Confirm the front clearance and recess depth for the exact mounting method.

Which pitch ranges do the two models cover?

EA250WH5 covers seven pitches from P1.25 GOB to P3.91. EA640H1 covers P1.25 to P2.5, with GOB on P1.25 to P2 models and SMD2020 on P2.5. Confirm the selected pitch and module protection in the quotation.

What should a shallow-recess quotation include for these walls?

Ask for separate lines for cabinet dimensions, module footprint, pitch, depth, mounting method, service route, front clearance, layout count, control, spares and freight. EA640H1 quote guidance asks for wall width and height, viewing distance, preferred pitch and delivery address, with an itemized quote covering cabinets, controller, spare modules and freight. EA250WH5 is quoted per project by pitch, wall size, cabinet quantity, control system, spare modules and shipping.

Are these two models suitable for outdoor use?

No. Both are indoor IP31 series with a -20 °C to +60 °C working range. Outdoor projects need a weather-rated cabinet and a higher IP rating.

Share your project requirements to request a quote.

CHECK THE DETAILS

Sources & references

Source pages can change. Access dates record when they were consulted.

  1. EA640H1 specs Accessed 23 September 2026
  2. EA250WH5 specs Accessed 23 September 2026

Put these details into your project brief.

Tell EagerLED the application, destination and screen dimensions you have in mind.