An EagerLED resource. Public-source references and technical guidance; not a binding quotation. Read our methodology.

Quick answer

Budget a mixed-format rental LED fleet with a model-by-model spare list, not one blanket spare ratio. For each EagerLED cabinet format in scope, separate spare modules, power boxes or power supplies, HUB boards, receiving cards, curve locks, corner protectors, removal tools and transport cases. Then request a written compatibility statement naming cabinet connections, pixel pitch and control configuration before combining formats in one wall.

Sources used: EA500H8 specs; EA576H1 specs; EA1000H9 specs; EA500C6 specs

Why One Blanket Spare Ratio Fails Across Formats

A mixed rental fleet can look uniform, but the documented service units differ. EA500H8 is a 500 x 500 mm cabinet using 250 x 250 mm modules; EA576H1 is a 576 x 576 mm cabinet using 288 x 288 mm modules; EA1000H9 is a 500 x 1000 mm cabinet using 250 x 250 mm modules; and EA500C6 is a 500 x 500 mm cabinet. A module spare for one format is not a universal module spare. Our advice is to keep a spare cabinet and module budget as separate model-level lines rather than one blanket percentage.

Cabinet weights and variants also change the spare line. EagerLED lists EA500H8 at 6.3 kg indoors or 6.5 kg outdoors, EA576H1 at 8 kg, EA1000H9 at 12 kg indoors or 13 kg outdoors, and EA500C6 at 6.5 kg indoors or 7.3 kg outdoors. Those figures describe the documented cabinets; they are not spare ratios. A spare cabinet line should name the exact model, indoor or outdoor variant, pitch and cabinet quantity, because indoor and outdoor configurations are documented separately.

The practical budget unit is the exact replacement part, not the fleet. For a mixed fleet, build one schedule per cabinet format and pitch, then add shared items such as control, transport and labour as separate lines. This keeps a 250 x 250 mm module spare from being counted against a 288 x 288 mm module format, and it makes a missing power box, HUB board or receiving card visible before the order is approved.

Build a Model-by-Model Spare Schedule

Start each schedule line with the cabinet model, cabinet size, module size, pixel pitch, indoor or outdoor variant and quantity. EagerLED documents EA500H8 as 500 x 500 mm with 250 x 250 mm modules, EA576H1 as 576 x 576 mm with 288 x 288 mm modules, EA1000H9 as 500 x 1000 mm with 250 x 250 mm modules, and EA500C6 as a 500 x 500 mm cabinet. The schedule should show the exact cabinet and module identity before any quantity is discussed.

Then add the service items that ride with that format. EA500H8 has a detachable back cover and a power box with a quick-release buckle plus a HUB connection design. EA576H1 has a removable power box and back cover plus HUB connection. EA1000H9 has a detachable power box and HUB board, and the power box opens from the rear. EA500C6 has an openable rear cover for the power and control area. Those are separate spare lines, not one generic cabinet-electronics line.

Documented handling hardware belongs on the same model line. EA500H8 lists four corner guards, quick locks, handles and locating slots. EA576H1 lists handles, fixing slots, quick locks and corner protectors. EA500C6 lists four corner protectors, dual quick locks, alignment pins, aluminium handles and stainless steel screws. EA1000H9 lists handles, locating slots and corner protection. Use those documented items when you ask for case and tooling scope for each format.

Spare-Part Lines to Budget by Cabinet Format

Decision Evidence to request
Cabinet and module identity Name the exact model, cabinet size, module size and pitch for each format: EA500H8 500 x 500 mm with 250 x 250 mm modules; EA576H1 576 x 576 mm with 288 x 288 mm modules; EA1000H9 500 x 1000 mm with 250 x 250 mm modules; EA500C6 500 x 500 mm.
Spare modules Match spare modules to the exact model and pitch; EA500H8 and EA1000H9 use 250 x 250 mm modules, while EA576H1 uses 288 x 288 mm modules.
Power box, HUB and receiving card Request separate lines for the power box or power supply, HUB board, receiving card and connectors; EA500H8 advises confirming matching power supply, receiving card and spare parts, and EA576H1 advises specifying compatible spare power supplies and receiving cards.
Curve hardware Confirm optional curve or arc locks for the exact model: EA500H8 optional high-precision curve lock; EA576H1 optional high-precision curved lock; EA1000H9 optional arc locks; EA500C6 optional concave and convex curve locks.
Corner protection and cases List four corner guards on EA500H8, corner protectors on EA576H1, corner protection on EA1000H9, and four corner protectors on EA500C6; request suitable transport cases and inspection per format.
Mixed-format compatibility Request written confirmation of cabinet connections, pixel pitch and control compatibility for EA500H8 mixed layouts, and matching pixel pitch and configuration for EA500C6 and EA1000C6 vertical mixed splicing.

Budget Power Boxes, HUB Boards and Receiving Cards by Exact Part

Power and control spares are model-specific in the supplied evidence. For EA500H8, technicians can remove the power box for service, and the source advises confirming the matching power supply, receiving card and spare parts when ordering a rental fleet. For EA576H1, the source advises specifying compatible spare power supplies and receiving cards with the order and confirming the supplied electronics and connection layout because project configurations may differ. Treat power-box spares as separate lines for each model and pitch.

The same discipline applies to the other formats. EA1000H9 places the power supply and HUB board in a detachable rear box wired on a HUB connection rather than individual module cables, so the unit swaps out without re-cabling the cabinet. EA500C6 has an openable rear cover for access to the power and control area, and its itemised quotation guidance names the controller, spare parts, rigging, flight cases and freight. If a fleet uses both formats, those lines should not be merged.

Our advice is to request a written part list for each cabinet format: power box or power supply, HUB board, receiving card, connectors, removal tools and any curve hardware. Then state whether each item is included, optional or quoted separately.

Locks, Corner Protectors and Cases Follow the Cabinet Format

Handling and alignment hardware differ by model even when cabinet footprints are similar. EA500H8 lists quick locks, handles and locating slots, plus four corner guards. EA576H1 lists quick locks, handles, fixing slots and corner protectors. EA500C6 lists dual quick locks, positioning pins, aluminium handles and four corner protectors. EA1000H9 lists handles, locating slots and corner protection. A mixed fleet should therefore carry model-specific lock, protector and alignment spares rather than one pooled handling kit.

Curve hardware is optional and model-specific. EA500H8 can form a curved LED wall only with the optional high-precision curve lock; specify a curved installation when requesting your quotation and confirm the available angle range and screen radius. EA576H1 uses an optional high-precision curved lock; request it when ordering a curved stage backdrop and confirm supported angles and layout. EA1000H9 uses optional high-precision arc locks, and the source says to order the arc locks together with the cabinets. EA500C6 lists optional concave and convex curve locks.

Transport cases and inspection routines should also be per format. The EA500H8 source advises suitable transport cases and says to inspect corners and locking points before each build, and it notes that corner protection does not replace careful handling. When you specify flight cases, use cabinet dimensions, cabinet weight and the exact model rather than a generic rental case size. Ask for packed dimensions and loaded weights for each format before you set case quantities.

Written Compatibility Statement for Mixed-Format Builds

A mixed-format fleet needs a compatibility statement, not just a cabinet count. EA500H8 cabinets support mixed layouts with EA500H7, EA500H8V and EA1000H8 cabinets, and the source asks buyers to confirm cabinet connections, pixel pitch and control compatibility before combining models in one video wall. EA500C6 and EA1000C6 cabinets support vertical mixed splicing for varied screen proportions, and the source says to confirm matching pixel pitch and configuration before combining cabinets. If the fleet mixes cabinet formats, keep mixed cabinet sizes as separate quotation lines.

The compatibility statement should name the exact cabinets, pitch, module grid and control configuration. The EA1000H9 source states that the 500 x 1000 mm cabinet bolts to the 500 x 500 mm EA500H9 horizontally and vertically on the same 250 mm module grid. That is a specific documented pairing, not a general rule for every 500 x 500 mm cabinet in a mixed fleet. Defer the final spare budget until the exact pairing and configuration are confirmed.

Our advice is to ask for written confirmation of four points: which cabinet models and pitches may share one wall; which spare parts are interchangeable across those models; which parts remain model-specific; and what control configuration is required. Treat a general statement that cabinets can be mixed as incomplete until those points are answered for the exact fleet.

Quotation Inputs and Budget Sequence for a Mixed Fleet

The quote inputs for a mixed fleet should be stated model by model. EA1000H9 guidance says price depends on pixel pitch, screen size, cabinet quantity, control system, spare modules and freight, and asks for width, height, viewing distance, indoor or outdoor use and delivery city before an itemised quotation. EA500H8 guidance asks for screen dimensions, viewing distance, indoor or outdoor location and flat or curved layout. EA576H1 guidance asks for wall dimensions, pixel pitch, installation method and delivery destination. Use the same line structure to compare LED screen quotes across suppliers.

A workable budget sequence is: fix the exact model, cabinet, module, pitch and indoor or outdoor variant; list main cabinets and spare items separately; add curve locks, corner protectors, removal tools and cases per format; add control, structure, power and signal distribution, freight, installation and commissioning; then request a written compatibility statement for any mixed-splicing build. For EA500C6, the source names the controller, spare parts, rigging, flight cases and freight as items an itemised quote should identify.

Do not approve one fleet-wide spare percentage before the format list is complete. The documented models use different module sizes, cabinet weights, service hardware and optional curve locks, so a single ratio hides which format is under-covered. Our advice is to set the spare quantity after the model-by-model schedule and compatibility statement are confirmed, not before.

Common Mistakes in Mixed-Format Spare Budgets

One mistake is treating a cabinet size as one spare format when the fleet may include different documented models. EA500H8 and EA500C6 are both 500 x 500 mm cabinets, but they are separate models with separate spare lines. EA576H1 is a 576 x 576 mm cabinet with 288 x 288 mm modules, while EA500H8 uses 250 x 250 mm modules. A module spare for EA500H8 should not be assumed to fit EA576H1.

Another mistake is leaving power boxes, HUB boards and receiving cards inside a cabinet price line. EA500H8 advises confirming the matching power supply, receiving card and spare parts; EA576H1 advises specifying compatible spare power supplies and receiving cards; EA1000H9 uses a detachable power box and HUB board; EA500C6 has an openable rear cover for power and control. Those items belong on separate lines.

A further mistake is assuming optional curve hardware is included. EA500H8, EA576H1, EA1000H9 and EA500C6 all list curve or arc hardware as optional or configuration-specific. Also compare complete offers with complete offers: if a quote leaves spare, case, freight or compatibility lines blank, treat those as unresolved rather than included. Defer the final spare budget if the supplier cannot name the exact cabinet, module, pitch, indoor or outdoor variant, power-box part, HUB board and receiving card for each format.

Mixed-Fleet Scenario and What to Confirm

Scenario What to confirm
500 x 500 mm and 576 x 576 mm fleet Keep modules, cabinets, corner protectors and cases on separate lines; EA500H8 uses 250 x 250 mm modules and EA576H1 uses 288 x 288 mm modules.
500 x 500 mm and 500 x 1000 mm fleet Confirm cabinet pairing and control; EA1000H9 bolts to EA500H9 on a 250 mm module grid, but that documented pairing is specific to those models.
Flat and curved builds Confirm optional curve or arc hardware for each model and whether it is included with cabinets or ordered separately.
Shared control system Ask which control configuration is required across the formats and which receiving cards or HUB boards remain model-specific.
Transport and storage Request packed dimensions, loaded case weight and case capacity per format; corner protection helps protect module edges but does not replace careful handling.

EA500H8 cabinet area

Illustrative calculation: 0.5 × 0.5 = 0.25 m². 500 mm cabinet side converted to metres; matches the source statement that one cabinet covers 0.25 m².

EA500H8 flat 4 x 3 m wall cabinet count

Illustrative calculation: 8 × 6 = 48 cabinets. Flat 4 x 3 m video wall using 500 x 500 mm cabinets, excluding support structure, as documented.

EA576H1 10-cabinet row length

Illustrative calculation: 10 × 0.576 = 5.76 m. 576 mm cabinet width converted to metres and multiplied by 10 cabinets, as documented.

EA500C6 4 m x 3 m screen cabinet count

Illustrative calculation: 8 × 6 = 48 cabinets. 4 m x 3 m screen using 500 x 500 mm cabinets; spare cabinets are additional, as documented.

Buyer checklist

  • Create one spare-parts line per cabinet model, pitch, indoor or outdoor variant and cabinet quantity.
  • List spare modules by exact module size and pitch; keep 250 x 250 mm and 288 x 288 mm module lines separate.
  • Separate power box or power supply, HUB board, receiving card, connectors, removal tools and technician time.
  • Confirm optional curve or arc hardware for each model and whether it must be ordered with the cabinets.
  • Request a written compatibility statement for any mixed-splicing build, naming cabinet connections, pixel pitch and control configuration.
  • Treat blank spare, case, freight or compatibility lines as unresolved rather than included.

Frequently asked questions

Should a mixed rental LED fleet use one blanket spare percentage?

No. Our advice is to budget by exact cabinet format and pitch. EA500H8 uses 250 x 250 mm modules, EA576H1 uses 288 x 288 mm modules, EA1000H9 uses 250 x 250 mm modules in a 500 x 1000 mm cabinet, and EA500C6 uses a 500 x 500 mm cabinet. A single percentage would not show which format is short of modules, power boxes, HUB boards or receiving cards.

What spare parts should be listed separately for each format?

List spare modules, power box or power supply, HUB board, receiving card, connectors, removal tools, curve locks, corner protectors and cases. EA500H8 advises confirming matching power supply, receiving card and spare parts; EA576H1 advises specifying compatible spare power supplies and receiving cards; EA1000H9 uses a detachable power box and HUB board; EA500C6 has an openable rear cover for power and control.

Can EA500H8 spare modules fit an EA576H1 cabinet?

Do not assume so. EA500H8 is documented with 250 x 250 mm modules, while EA576H1 is documented with 288 x 288 mm modules and a 576 x 576 mm cabinet. Match each spare module to the exact model, pitch and indoor or outdoor variant.

What should a mixed-format compatibility statement include?

It should name the exact cabinet models, cabinet connections, pixel pitch and control compatibility. For EA500H8 mixed layouts, the source asks to confirm cabinet connections, pixel pitch and control compatibility before combining models. For EA500C6 and EA1000C6, the source says to confirm matching pixel pitch and configuration before combining cabinets.

How should curve hardware be budgeted in a mixed fleet?

Treat it as optional and model-specific. EA500H8 lists an optional high-precision curve lock; EA576H1 lists an optional high-precision curved lock; EA1000H9 lists optional high-precision arc locks that should be ordered together with the cabinets; EA500C6 lists optional concave and convex curve locks. Confirm angle range or radius and inclusion for each model.

What quotation lines help compare mixed-format spares?

Separate cabinets, video controller, mounting structure, power and signal distribution, spare modules, freight, installation and commissioning. For EA500C6, the source says an itemised quote should identify the controller, spare parts, rigging, flight cases and freight. Use the same line structure for each format.

Share your project requirements to request a quote.

Check the details

Sources & references

Source pages can change. Access dates record when they were consulted.

  1. EA500H8 specs Accessed 30 September 2026
  2. EA576H1 specs Accessed 30 September 2026
  3. EA1000H9 specs Accessed 6 October 2026
  4. EA500C6 specs Accessed 30 September 2026

Put these details into your project brief.

Tell EagerLED the application, destination and screen dimensions you have in mind.

Request a project quote