Quick answer
For a bus shelter or street furniture screen, shortlist a documented outdoor-rated cabinet and match pitch to the closest regular pedestrian and driver. The EagerLED EA1920OP2 is a movable double-sided outdoor poster with IP65 front and rear and 5,000 cd/m², while the EA576H1 is an outdoor rental cabinet with IP65 front, IP54 rear and 4,500 cd/m². Confirm the exact quoted configuration, then scope service, power, data and permissions.
Sources used: EA1920OP2 specs; EA576H1 specs; EA1920iP4 specs; Church LED Display Guide &
Choose a documented outdoor cabinet before assuming a bus-shelter product
There is no bus-shelter-specific model in the supplied evidence, so begin with a cabinet documented for outdoor use and confirm the exact application. The EagerLED EA1920OP2 is a 640 × 1920 mm double-sided foldable poster with P1.86, P2 and P2.5 options, 5,000 cd/m² brightness, at least 3840 Hz refresh, IP65 protection on the front and rear, rear service access and four transport wheels. Its source lists outdoor events, retail promotions and temporary advertising, so it suits a movable or temporary street-furniture placement where those conditions apply.
For a more cabinet-based street-furniture build, the EagerLED EA576H1 is a 576 x 576 mm outdoor rental cabinet, 8 kg, with P3.79 or P4.8, 4500 cd/m², at least 3840 Hz refresh, a 140° viewing angle, 288 x 288 mm modules, front and rear service, a removable power box and an optional high-precision curved lock. Its source describes rental companies, event production teams and exhibition contractors building temporary video walls, so confirm whether the bus-shelter design is fixed or temporary before treating it as a permanent furniture solution.
Do not assume an indoor poster is outdoor-rated. The EagerLED EA1920iP4 is documented as a 640×1920 mm foldable LED poster display built for double-sided indoor advertising, with P1.25 to P2.5, SMD/GOB or flip-chip COB modules and 600–800 cd/m² brightness. The supplied passage does not document an outdoor IP rating for it, so ask for written confirmation if it is being considered for any exposed bus-shelter position.
Match pixel pitch to the closest pedestrian and driver
Treat the bus shelter as two sightline problems: the pedestrian who stands next to the glass and the driver or passenger who reads from the road or pavement. The EA1920OP2 offers P1.86, P2 and P2.5 and documents a 160° viewing angle; the EA576H1 offers P3.79 or P4.8, a 140° viewing angle and listed module resolutions of 76 x 76 pixels and 60 x 60 pixels respectively. None of those figures sets a bus-shelter rule, so use a pixel pitch and viewing distance method, then test actual route numbers, timetable text and short notices at the closest regular position and at side angles.
If the shelter screen is close to pedestrians, fine text such as a route number or stop name matters more than distant advertising. If the main viewer is in a passing vehicle, test the same text at the driver’s approach and at the side of the shelter. Keep the test content specific: a short route number, a timetable line, a safety message and a brand line. Ask for a content demonstration for the intended audience distance rather than selecting by pitch alone.
Bus shelter LED display decisions and evidence to request
| Decision | Evidence to request | Documented reference |
|---|---|---|
| Movable double-sided street poster | Confirm role for temporary or movable placement and two-way visibility. | EA1920OP2: 640 × 1920 mm double-sided foldable poster; P1.86/P2/P2.5; 5,000 cd/m²; at least 3840 Hz; IP65 front and rear; rear service; 58.2 kg; four wheels. |
| Fixed or rental street-furniture cabinet | Confirm fixed or temporary build and the outdoor service route. | EA576H1: 576 x 576 mm outdoor rental cabinet; 8 kg; P3.79 or P4.8; 4500 cd/m²; at least 3840 Hz; 140°; IP65 front and IP54 rear; front and rear service; optional curved lock. |
| Indoor poster option | Do not assume an indoor poster is outdoor-rated; request written confirmation for any exposed position. | EA1920iP4: 640×1920 mm foldable poster built for double-sided indoor advertising; P1.25 to P2.5; SMD/GOB or flip-chip COB; 600–800 cd/m²; at least 3840 Hz. |
| Pixel pitch and sightlines | Name the closest regular pedestrian and driver positions and test route numbers, timetable text and notices. | EA1920OP2 P1.86/P2/P2.5 and 160° viewing angle; EA576H1 P3.79/P4.8 and 140° viewing angle. |
| Daylight brightness | Confirm brightness for the exact quoted pitch and configuration, not a series headline. | EA1920OP2 5,000 cd/m²; EA576H1 4500 cd/m² across both P3.79 and P4.8 listed configurations. |
| IP protection by face | Confirm the written IP rating for each exposed face, including cable entries and service openings. | EA1920OP2 IP65 front and rear; EA576H1 IP65 front and IP54 rear, with different ratings on the two sides. |
| Power, data and service | Confirm power standard, data path, typical and maximum power, and who can access the service position. | EA1920OP2 rear control panel: HDMI input/output, USB 3.0, Ethernet, power input/output, volume control and built-in speakers; EA576H1 HUB connection, removable power box, front and rear service. |
Confirm daylight brightness and plan night limits
Brightness should be quoted for the exact configuration. The EA1920OP2 lists 5,000 cd/m², and its source says that brightness supports daylight visibility. The EA576H1 lists 4500 cd/m² across both P3.79 and P4.8 configurations. Confirm the quoted pitch and brightness rather than a series headline, and check the actual orientation at the sunniest time of day.
Night operation is a separate requirement. EagerLED’s outdoor signage guidance says to confirm local sign rules and brightness limits before installation. Ask whether the quoted control system supports separate day and evening brightness settings, and treat outdoor LED night dimming as a written quotation item rather than assuming it is included.
Check IP protection and weather exposure face by face
Weather protection is not one label for the whole shelter. The EA1920OP2 records IP65 protection on the front and rear. The EA576H1 specifies IP65 at the front and IP54 at the rear, and its source notes that the two sides have different ratings. For a street-furniture position, mark each face as directly exposed, sheltered or dry, then ask for the written IP rating for the exact cabinet, including cable entries, service openings, power box and module edges.
Use the IP31, IP54 and IP65 comparison to frame that question, but do not treat it as site approval. The EA576H1 source also says to check the complete installation requirements for the outdoor venue. If the rear of the cabinet faces rain or spray, ask the supplier to confirm in writing whether the documented rear IP54 rating suits that exposed face and what orientation, shroud or other protection the supplier recommends for the actual mounting position.
Plan power, data and service access inside the street furniture
Service access should be chosen before the screen position is fixed. The EA1920OP2 documents rear service access and an openable back cover; its source says technicians can reach the service area without disassembling the front display surface. The EA576H1 documents front and rear service access, a removable power box and back cover, and a HUB connection design. EA1920OP2 also has a rear control panel with HDMI input and output, USB 3.0, Ethernet, power input and output and volume control, plus built-in speakers.
For the quote, provide the screen width and height, nearest and farthest viewing distances, indoor or outdoor location, mounting method, power standard, delivery destination and target installation date. Ask for separate lines for cabinets, video controller, mounting structure, power and signal distribution, spare modules, freight, installation and commissioning, and ask the supplier to state proposed pixel pitch, active resolution, typical and maximum power, cabinet quantity, service method and warranty scope. Use a compare LED screen quotes method so each offer uses the same rows.
Treat permissions, vandal resistance and operating temperature as written project items
EagerLED’s outdoor signage guidance says to confirm local sign rules, brightness limits, structural requirements and viewing direction before installation. It also says to confirm wall loading, ventilation, cable routes, power distribution, grounding and service access with qualified project professionals. For a bus shelter, apply those checks to the shelter structure and the relevant local authority, and keep approval, structural design and electrical design outside the cabinet line so each scope can be reviewed separately.
Ask the supplier to state the operating-temperature range and any front-surface protection information for the exact quoted configuration, because those are model-specific project items. For any filmed or camera-facing location, test the actual camera, shutter and processor settings before the event, as the EA576H1 source advises.
Bus shelter scenarios and what to confirm
| Scenario | What to confirm |
|---|---|
| Temporary or movable bus-stop promotion | Confirm the EA1920OP2 double-sided foldable poster format, four wheels, IP65 front and rear, 5,000 cd/m² and P1.86/P2/P2.5 options for the exact placement. |
| Fixed shelter with no rear access | Confirm the EA576H1 front and rear service route, module removal method, working clearance and spare-module handling for the installed position. |
| Exposed rear face | Ask the supplier to confirm in writing whether the documented EA576H1 rear IP54 rating suits the actual exposure, and what orientation or additional protection is recommended. |
| Close pedestrian reading of route numbers | Test the smallest route number and timetable text at the closest regular position; EA1920OP2 documents 160° and EA576H1 documents 140° viewing angles. |
| Daylight and night operation | Confirm brightness for the exact quoted configuration and ask for night dimming as a written quotation item; local brightness limits are project-specific. |
| Street furniture permits and structure | Confirm local sign rules, brightness limits, structural requirements and viewing direction before installation. |
Buyer checklist
- Mark each face of the proposed bus shelter cabinet as directly exposed, sheltered or dry, then request the written IP rating for each exposed face; EA1920OP2 records IP65 front and rear, and EA576H1 records IP65 front and IP54 rear.
- Measure the closest regular pedestrian and driver position and test the smallest route number, timetable line and notice text at the quoted pitch; EA1920OP2 offers P1.86, P2 and P2.5, and EA576H1 offers P3.79 or P4.8.
- Confirm daylight brightness for the exact quoted configuration and check local night brightness limits; EA1920OP2 lists 5,000 cd/m² and EA576H1 lists 4,500 cd/m².
- Choose the service route before fixing the position; EA1920OP2 documents rear service, and EA576H1 documents front and rear service.
- Provide quote inputs and ask for separate lines for cabinets, video controller, mounting structure, power and signal distribution, spare modules, freight, installation and commissioning.
- Treat vandal resistance, operating-temperature range and local permissions as written project questions rather than inferring them from an outdoor IP rating.
Frequently asked questions
Which EagerLED cabinet should a bus shelter or street furniture project shortlist?
The EA1920OP2 is a movable double-sided outdoor poster with IP65 front and rear, 5,000 cd/m², P1.86/P2/P2.5 and rear service. The EA576H1 is an outdoor rental cabinet with IP65 front and IP54 rear, 4500 cd/m², P3.79 or P4.8 and front and rear service. EA1920iP4 is documented for indoor advertising, so confirm an outdoor rating before considering it for an exposed bus shelter.
What pixel pitch should a bus shelter LED display use?
There is no single bus-shelter pitch. EA1920OP2 offers P1.86, P2 and P2.5, while EA576H1 offers P3.79 or P4.8. Measure the closest regular pedestrian and driver positions, then test route numbers, timetable text and short notices at the quoted pitch and at side angles.
Is IP65 enough for a bus shelter LED display?
Confirm the written IP rating for each exposed face. EA1920OP2 records IP65 front and rear. EA576H1 records IP65 front and IP54 rear, and its source notes those two sides have different ratings, so ask the supplier to confirm whether the documented rating for each face suits the actual mounting orientation and exposure.
How should power and data be planned for a street furniture screen?
EA1920OP2 has a rear control panel with HDMI input and output, USB 3.0, Ethernet, power input and output, volume control and built-in speakers. EA576H1 has a HUB connection design and a removable power box. Ask the supplier for typical and maximum power for the exact configuration and keep power and signal distribution on separate quotation lines.
Do bus shelter screens need planning permission?
EagerLED’s outdoor signage guidance says to confirm local sign rules, brightness limits, structural requirements and viewing direction before installation. Those checks are project-specific, so confirm them with the relevant authority and qualified project professionals for the actual bus shelter location.
Can a bus shelter use an indoor foldable poster?
EA1920iP4 is documented as a 640×1920 mm foldable poster display built for double-sided indoor advertising, with 600–800 cd/m² brightness and P1.25 to P2.5. The supplied passage does not document an outdoor IP rating for it, so do not assume it for an exposed bus shelter and request written confirmation if it is being considered.
Share your project requirements to request a quote.
Check the details
Sources & references
Source pages can change. Access dates record when they were consulted.
- EA1920OP2 specs Accessed 28 September 2026
- EA576H1 specs Accessed 30 September 2026
- EA1920iP4 specs Accessed 30 September 2026
- Church LED Display Guide & Accessed 28 September 2026
Put these details into your project brief.
Tell EagerLED the application, destination and screen dimensions you have in mind.
Request a project quote